SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps98
© 2012 Datacom Systems Inc
STATUS current
DESCRIPTION
"The value of sysUptime when this power supply
transitioned into its current state.
A value of zero(0) indicates this power supply was
already in its current state when the SNMP agent last
re-initialized.
"
::= { dcomPowerSupplyStatusEntry 3 }
--
-- power supply event notifications
--
dcomPowerSupplyEventUp NOTIFICATION-TYPE
OBJECTS { dcomPowerSupplyStatus
}
STATUS current
DESCRIPTION
"A dcomPowerSupplyEventUp event notification
provides an indication that a power supply has
transitioned into the 'up' state.
The power supply involved in this event is
identified by the dcomPowerSupplyIndex value
appended to the object name of the
dcomPowerSupplyStatus variable binding.
"
::= { dcomPowerSupplyEventsNotify 1 }
dcomPowerSupplyEventDown NOTIFICATION-TYPE
OBJECTS { dcomPowerSupplyStatus
}
STATUS current
DESCRIPTION
"A dcomPowerSupplyEventDown event notification
provides an indication that a power supply has
transitioned into the 'down' state.
The power supply involved in this event is
identified by the dcomPowerSupplyIndex value
appended to the object name of the
dcomPowerSupplyStatus variable binding.
"
::= { dcomPowerSupplyEventsNotify 2 }
Vedere la pagina 97